Entrained Gas Contamination in Lube Oil System of Large Gas Compressor

Kristen Modzelewski

Problem:

At a large Petrochemical facility near Houston, Texas, there was ingression of Acetylene Gas through a leaking seal into the 750-gallon lube oil system of a Gas Compressor. High concentrations of light end hydrocarbon gases (including H2S, Benzene, Toluene, and Acetylene) drive down the flashpoint of compressor oils to very low and dangerous levels, and they also adversely affect the viscosity of the ISO VG 32 compressor oil, inhibiting its ability to act as an effective lubricant.



Because the Gas Compressor could not be shut down to fix the seal leak without incurring a tremendous cost in manpower and down-time, and because the next scheduled turn-around was not for another year, operators at the plant were “sweetening” the oil on a regular basis in an effort to maintain a proper flashpoint and viscosity. New oil was introduced through the fill port while old oil was drained off of the bottom. The cost to purchase new oil is very expensive (roughly 1,500 gallons per month at $18.50 per gallon = $27,750 per month x 12 = $333,000 per year), with an additional labor cost involved as well.


Solution:

As an alternative, the plant decided to implement a trial 20 GPM Vacuum Dehydration Oil Purification System (VDOPS) to re-circulate the lube oil reservoir in a kidney-loop configuration and continuously remove entrained gases from the oil as the compressor was running. The VDOPS needed to be suitable for Class 1, Division 2, Groups B,C&D hazardous locations, and the gases that were removed from the oil via “vacuum distillation” had to be plumbed to a flare from the discharge of the vacuum pump. While the VDOPS was re-circulating on the reservoir, excellent results were achieved and well documented.


Results:

In February, the starting flashpoint of the oil was as low as 105, and the viscosity was 20.5 cSt. In May, the flashpoint had risen to 145 and the viscosity was 22.9 cSt. By July, the flashpoint had risen significantly to 190, and the viscosity was 23.7 cSt.


Return on Investment:

Due to the implementation of a 20 GPM Vacuum Dehydration Oil Purification System on this Gas Compressor, and because of the successful performance and results, the plant no longer needs to “sweeten” the oil at a cost of $333,000 per year.


After the trial, a new fully equipped VDOPS was put in place within weeks. With a purchase price of $72,000 for the 20 GPM NEMA 7 VDOPS, and with virtually no consumables required for the effective removal of entrained gases from the oil, the ROI for the plant was under 3-months.

27 views0 comments

Comments


Commenting has been turned off.

CALL US

Tel: +1 (830) 816-3332

EMAIL US

ADDRESS

135 Enterprise Parkway

Boerne, Texas 78006

About Oil Filtration Systems®

  • YouTube
  • Facebook

Oil Filtration Systems® manufactures Oil Purification Equipment designed to remove contamination (water, particulate, varnish, and/or entrained gases) from a wide variety of fluids, including Turbine Oil, Hydraulic Oil, Gear Oil, and Fuel Oil (#2 Diesel Fuel).  When used in conjunction with our high-efficiency filter elements rated Beta(c)>1000 in a variety of micron sizes, our systems will enable you to achieve optimal fluid cleanliness to meet or exceed the most stringent OEM cleanliness specifications.

We also operate the largest, newest, and best maintained Rental Fleet of highly advanced oil and fuel purification equipment in the industry. In addition, our Field Services Division has highly qualified and experienced technicians performing a variety of filtration and flushing services worldwide.  We mobilize quickly for emergency outages, scheduled outages, routine maintenance, and pre-commissioning of new equipment.

 

WE SET THE STANDARD FOR OIL PURIFICATION™

Copyright © 2022 Clark-Reliance. All Rights Reserved.

bottom of page